• 1
  • 2
  • 3
  • 4
  • 5

Grid Stability - How secure …

Grid Stability - How secure is our electricity supply?

Dear Sir or Madam,   The economic pressure to...

Anwendertreffen "Mobile…

Anwendertreffen "Mobile Power Quality"

Sehr geehrte Damen und Herren,   hiermit möchten wir...

Kostenintensiven Netzausbau …

Kostenintensiven Netzausbau vermeiden

Sehr geehrte Damen und Herren,    die Niederspannungsnetze befinden...

2014 German Economy Innovati…

2014 German Economy Innovation Award

A. Eberle GmbH & Co. KG has...

HMI 2014: Technology meets p…

HMI 2014: Technology meets progress

Dear Sir or Madam, In the run-up...

Seminar with OMICRON

Seminar with OMICRON

Ladies and gentlemen, Due to the big interest...

RESys™ with useful add-on fu…

RESys™ with useful add-on functionality

The well-known REGSys™ consisting of REG-D™ and...

The first Multi-App of A. Eb…

The first Multi-App of A. Eberle is available!

Dear Sirs and Madams, today I am very...

Trade-fair appearances 2014

Trade-fair appearances 2014

Here can you find the foresight...

Voltage Regulation and Rever…

Voltage Regulation and Revers Power Flow

Decentralised power generation is now and...

Low Voltage Regulation Syste…

Low Voltage Regulation System LVRSys

The Low Voltage Regulation System LVRSysTM...

„Stove phenomenon“ - system…

„Stove phenomenon“ -  system perturbations

Example for system perturbations. Mobile Power Quality-Analyzers...

Member of the network SmartG…

Member of the network SmartGrids

A. Eberle GmbH & Co. KG...

A. Eberle is a partner of th…

A. Eberle is a partner of the E.ON Bayern

A. Eberle is a partner of...

PQ Box 100 – „Recalibration“…

PQ Box 100 – „Recalibration“  Service Packs

Dear Sir or Madam, Initiated by the exhibition...

Grid Dynamics Analyzing (GDA…

Grid Dynamics Analyzing (GDA) – monitoring of dynamics

The Grid Dynamic Monitoring Relay DMR-D and...

Seminars 2014

Seminars 2014

Contact us directly via info@a-eberle.deEsta dirección...

Always one step ahead

Always one step ahead

We do our best to constantly...

Job offers 2014

Job offers 2014

Here you can view our current job...

REG-DA

Voltage Regulator REG-DA

Application
All measurement, control and regulation tasks of tap-changing transformers can be executed using the new REG-DA voltage regulator.

The REG-DA regulator features a world innovation as it is equipped with a high-capacity transformer monitoring function in accordance with CEI IEC 354 (VDE 0536). This function allows the operator to call up information about the hot-spot temperature and the lifetime consumption of the transformer at any time. If required, the regulator can even activate up to six cooling levels. The oil temperature can either be recorded directly (PT 100) or via a mA input.

Apart from its basic function, every REG-DA voltage regulator can be used as a measurement transducer, recorder, statistical unit, paragramer and transformer monitor all at the same time. All important network measurement quantities are displayed in measurement transducer mode. The trends in the voltage that is to be regulated over time and a second, selectable, measurement quantity are shown in recorder mode. The statistical unit for the tap-change position offers a clear presentation of all switching operations of the tap changer. The paragramer provides a complete busbar simulation.

Interconnection of multiple voltage regulators on a network enables the mutual exchange of data between regulators over long distances.Various communications methods can be used to transfer data.This allows monitoring of multiple transformers from a centralised control centre. Parallel connection of several transfomers can be very easily implemented this way. Application-specific tasks can be implemented via freely programmable inputs and outputs. The REG-DA regulator is able to communicate with a control centre via all common scada protocols.

Characteristics of the REG-DA voltage regulator• large backlit LCD (128 x 128) with all important information (tap-changer position,
  voltage, etc.)
• Measuring functions (U, I, P, Q, S, cos ϕ, ϕ, I sin ϕ, f )
• Recorder functions (2-channel chart recorder)
• Statistics functions (records total number of switching operations, switching
   operations per tap)
• Event recorder (log book)
• Transformer monitoring functions incl. recording of the hot-spot temperature and
   lifetime consumption
• 14 (26) freely programmable binary inputs• 9 (21) freely programmable binary
   outputs
• Freely programmable analogue inputs or outputs (mA)
• Pt 100  direct input for RTD temp. probe (option)• Input for tap-potentiometer (200Ω...20kΩ  total resistance, option)
• Control of three-winding transformers
• Control of phase-shifting transformers
• Limit value monitoring for all measurement quantities
• 4 freely programmable set-point values
• Programmable rated values of U and I
• Parametric software WinREG for setup, programming and display
  as well as for PC-based archiving and evaluation of the recorder data
• Simulation software REGSimTM for the simulation of any parallel operation, network
  and load situations
• Implementation of freely programmable control tasks through
• Peripheral bus RS 485 (COM3) for additional interface modules (ANA-D, BIN-D)
• ParaGramer function for the display and automation of any parallel connections
  with up to ten transformers
• UL-certification
 