»Cyber Security« Webinar: A Challenge for European Energy Companies
Webinar recording from 2025-11-26: »Cyber Security« - A Challenge for European Energy Companies
»PQMobil« Training Video 8: Setting up remote access for the PQ-Box
This video shows how to configure a PQ-Box remotely via Wi-Fi, LAN, network, and the Internet using a VPN tunnel, view live data, and transfer measurement data. Enjoy the video.
Total Harmonic Distortion (THD) in Low Voltage Networks
This study examines harmonic distortion in modern low-voltage grids, showing real measurement data, key standards (EN 50160, IEC 61000-3-2/-4-30) and practical ways to reduce THD in applications such as EV charging, PV systems, battery storage and hybrid working environments.
Power Quality Monitoring in Buildings - A Key Factor in Modern Building Design
Discover how Power Quality Monitoring in Buildings improves reliability, efficiency and grid stability. Learn more in our technical article.
Continuous Power Quality Monitoring in the Jupiter Data Centre - Voltage Quality at Exascale Level
With JUPITER, Forschungszentrum Jülich operates Europe's fastest supercomputer and sets new standards for energy efficiency, grid stability, and standard-compliant power quality with PQSys from A. Eberle.
»PQSys« Webinar: »WebPQ®« - The New Power Quality Software for Continuous Grid Monitoring
Webinar recording from 2025-09-25: »PQSys« Webinar: »WebPQ®« - The New Power Quality Software for Continuous Grid Monitoring
Voltage Measurement Can Improve the Quality of Supply
A short study by EWI and Fraunhofer IEG shows that mandatory voltage measurements and stricter regulation of voltage quality are necessary to ensure grid stability in Germany in light of the energy transition.
Power in Multiphase Systems
This technical report highlights the special features of power transmission in three-phase systems and offers valuable insights into the optimisation and analysis of modern power grids.
»PQMobil« Webinar: New Features/Functions for Your PQ-Box/es: Presentation of WinPQ mobil V8 & V7 legacy
Webinar recording from 2025-07-29: »PQMobil - New Features/Functions for Your PQ-Box/es: Presentation of WinPQ mobil V8 & V7 legacy«.
»PQSys« Webinar: PQ-Monitoring & Feeder Current Measurement in Low-Voltage Grids 3
Webinar recording from 2025-05-14: »PQSys - PQ-Monitoring & Feeder Current Measurement in Low-Voltage Grids - part 3«.
»PQMobil« Webinar: Power Quality Analysis in Public & Industrial Power Grids – Part 3
Webinar recording from 2025-04-02: »PQMobil - Power Quality Analysis in Public & Industrial Power Grids – Part 3«.
»PQMobil« Training Video 7: Measurement Data
This video is all about the measurement data. What data does the PQ-Box record and what is the best way to configure it beforehand?
»PQSys« Webinar: Presentation: »PQI-LV« - The New PQ-Analyser for Transparency in the Low-Voltage Grid
Webinar recording from 2025-02-19: »PQSys - Presentation: »PQI-LV« - The New PQ-Analyser for Transparency in the Low-Voltage Grid«.
Measuring the Voltage Drop
The voltage drop is the difference between the voltage at the beginning and end of an electrical line. In an electrical network, the voltage can be reduced by the resistance and impedance of the lines, resulting in a lower voltage reaching the consumer than was originally fed in. Find out everything about measurement and calculation in this article!
»PQSys« Training Video 1: Presentation New Functions of Firmware V3.2 for PQI-LV, PQI-DA smart & PQI-DE
In this video, we present the new functions and extended options with firmware version 3.2 for our fixed installed power quality analysers and fault recorders PQI-LV, PQI-DA smart and PQI-DE of the PQSys product range. Find out in just three minutes how the new firmware expands the application and operating options of your A. Eberle measuring devices.
»PQMobil« Webinar: Power Quality Analysis in Public & Industrial Power Grids – Part 2
Webinar recording from 2024-11-13: »PQMobil - Power Quality Analysis in Public & Industrial Power Grids – Part 2«.
»EOR-3DS« & »PQSys« Webinar: Digitise and monitor local network substations for the future with »EOR-3DS« & »PQSys«
Webinar recording from 2024-10-10: »EOR-3DS« & »PQSys - Digitise and monitor local network substations for the future with »EOR-3DS« & »PQSys««.
Harmonics
Harmonics are waves whose frequencies are an integer multiple higher or lower than those of the fundamental oscillations. They arise due to non-linear loads in the grid when the electrical voltage is distorted due to various influencing factors. Learn more about harmonics in this article!
»PQMobil« Training Video 6: Presentation of WinPQ Mobile 7.1
In this video we introduce you to all the new features & functions of the latest version of the analysis software »WinPQ mobil 7.1« for our portable power quality analysers. Enjoy the video and the new possibilities with your PQ-Box from A. Eberle.
»PQMobil« Training Video 5: Trigger and Fault Record Settings
Discover the best trigger settings for your »PQ-Box« to accurately record network disturbances. The video shows how to configure the half-cycle, oscilloscope, and transient recorders to reliably capture essential measurement data.
»PQSys« Webinar: PQ-Monitoring & Feeder Current Measurement With PQSys
Webinar recording from 2024-08-06: »PQSys - PQ-Monitoring & Feeder Current Measurement with PQSys«.
Voltage Monitoring
Find out everything you need to know about voltage monitoring in this article. What is voltage monitoring, why is voltage monitoring essential for both energy supply companies and industrial companies and how is it implemented in compliance with standards?
What Is Load Profile Measurement/Power Measurement?
This article explains the definition and difference between load profile measurement (RLM), power measurement and measuring the standard load profile. These are important methods for accurately recording energy consumption in commercial, large industrial plant as well as in the public energy grid.
»PQMobil« Training Video 4: Create and Configure PQ Reports With Software WinPQ Mobil
This video explains everything about creating and configuring power quality reports with »WinPQ mobil«.
»PQMobil« Webinar: Power Quality Analysis in Public & Industrial Power Grids – Part 1
Webinar recording from 2024-02-22: »PQMobil - Power Quality Analysis in Public & Industrial Power Grids – Part 1«.
»PQSys« Webinar: PQ-Monitoring & Feeder Current Measurement in Low-Voltage Grids
Webinar recording from 2024-04-17: »PQSys - PQ-Monitoring & Feeder Current Measurement in Low-Voltage Grids«.
»PQMobil« Training Video 3: Usability & Functions of the PQ-Box App
This video gives you an introduction to the usability and functions of the »PQ-Box App« for our portable power quality analysers.
»PQMobil« Training Video 2: Menu Navigation and Operation of the PQ-Box
In this short introductory video, we present to you how to navigate and operate our portable power quality analysers »PQ-Box 150«, »PQ-Box 200« & »PQ-Box 300« of the PQ-Box family.
»PQMobil« Training Video 1: Getting Started With the PQ-Box
This video shows in detail how to connect the »PQ-Box« and record measurements. The »WinPQ mobil« software is then used to visualize and analyse the measurement data and create a report.
Ferrari´s Meter vs. Electronic Meter
This technical report analyzes a power measurement at a large industrial customer. The customer records very high currents and fifth harmonic voltages during production time, which leads to poor voltage quality.
Residual Current
In this article, you will learn about residual current measurement & residual current monitoring and why it is important to measure residual current.
Power Quality
Good power quality is characterized by the fact that the mains voltage actually arriving at the consumer matches the mains voltage promised by the utility company.
Reactive Power - Definition, Calculation and Measurement
The key role of reactive power in electrical engineering: definition, calculation, measurement and the differences to active power and apparent power. Find out how reactive power influences the efficiency of electricity grids and shapes energy transmission.
What Is Apparent Power and How Is It Calculated?
This article addresses the question of what apparent power is and how to calculate it. An understanding of apparent power is crucial for the correct dimensioning of inverters and therefore for the optimum efficiency and performance of photovoltaic systems.
Ready for the Smart Grid of the Future?
All information about smart grids/intelligent power grids, the technology behind them, advantages, disadvantages, challenges and current distribution.
Angle Determination of Voltage and Current Harmonics in Practice
Today's devices and equipment such as switched-mode power supplies, frequency converters, regulated drives, charging devices for e-mobiles or LED lighting work internally with high clock frequencies in order to regulate power efficiently. These can lead to both conducted and field-bound (coupled) influences in the energy grid. In this technical report, we explain how you can detect these sources of interference in the grid using suitable measuring technology.
All „Supra“ With Your Grid?
Today's devices and equipment such as switched-mode power supplies, frequency converters, controlled drives, charging devices for e-mobiles or LED lighting work internally with high clock frequencies in order to regulate power efficiently. These can lead to line-borne as well as field-borne (coupled) interference in the power grid. In this technical report, we explain how you can detect these sources of interference in the grid using suitable measurement technology.
Power Quality Analysis: Tips and Tricks II
Useful tips & tricks for handling Power Quality measuring devices and typical user errors - now in our two-part article! This article provides further insights and practical tips and application examples for power quality analysis.
Power Quality Analysis: Tips and Tricks I
Useful tips & tricks for handling Power Quality measuring devices and typical user errors - now in our two-part article! This article explains tips and tricks for performing power quality measurements. It explains which connection errors can be made and which preliminary considerations should be made before using a measuring device.
Four Ways to Measure Current
The following technical report examines various methods for measuring current. It discusses how currents are measured using power analyzers and current clamps. The respective advantages and disadvantages of different technologies such as shunts, normal current clamps, hall effect sensors, etc. ar also evaluated.
Cos ϕ vs. Power Factor λ - Practice
This second technical report on the subject of reactive power and in particular the distortion reactive power supplements the first contribution "Cos ϕ vs. power factor λ – Theory". In this article, the voltage and current of an incandescent lamp are measured in an online measurement using a power analyzer.
Cos ϕ vs. Power Factor λ - Theory
This technical report discusses the distinction between power factor and cosine phi. Cosine Phi, formerly widely known as the ratio of active power to apparent power, however, has a different meaning for many consumers today.
Innovative & Economical “System Solutions” in the Age of Energy Grid Transformation
The transformation of the energy industry from a centralized structure to a decentralized energy supply is creating complex energy networks with volatile load flows and changing load flow directions. Grid feedback effects must be reduced to a tolerable level to avoid negative effects.
Mains Feedback Interferes With Protective Devices
In a photography and design studio, located in a large industrial park, a RCD tripped frequently. Due to the permanent power cuts, the employees of the studio could not work properly. This article shows how we found a solution for this problem using our Power Quality devices.
Creating Power Quality Surveys With PQ-Box and WinPQ Mobil Software
The following report displays the PQ-Box and WinPQ mobil software interact to allow an evaluation of the disturbance levels at a measuring point according to approved grid norms.
Measurement of Voltage Distortions in Industrial Grids With the PQ-Box 50
It is important to find disturbances in the system in a fast and reliable way. This report shows an example for trouble shooting with the Power Quality analyzer PQ-Box 50.
Power Quality Measurements: The Third Harmonic
This special publication intends to illustrate a typical power quality measurement and the aspects, which should be taken into consideration conducting the measurements.
Power Quality Measurements: The N-Conductor & Harmonics
In power quality measurements, odd harmonics such as the 15th, 21st & 27th are often violated. What are harmonics anyway, how does this circumstance occur and what influence does this have on the neutral conductor.
Information Letter No. 24: Integration guide for the metering of a power plant according to the Requirements for Generators (2016/631) RfG
Integration guide for the measurement of a power plant (EZA) according to VDE-AR 4110 and VDE-AR 4120.
Changes in Energy Technology - Part 2
Standards play a major role for power quality measurements. Accordingly, it is essential that these standards are also adapted to the new conditions in the course of the change in energy technology.
Changes in Energy Technology - Part 1
In this article we discuss the current changes in the energy technology. In addition, we will look on the effects of grid repercussions and what influence they have on measuring devices with which we detect faults in the grid.
Info Letter No. 23: Direction of Harmonics Sources of Harmonics in the Power System
Le sens du flux de puissance des harmoniques est déterminé par le signe de la puissance activ
Info Letter No. 22: Definition of Power Measurements According to the Standards DIN 40110-2 and IEEE 1459
There is a wide range of electronic measuring devices for the digital measurement of power...
Info Letter No. 20: Capacitance of Conductors
In the conductors of electrical power supplies, a distinction is made between the operating capacitance...
Info Letter No. 19: The Evaluation of Power Quality and Detection of Interference in Medium Voltage Network
For various reasons, interest in the continuous monitoring of network quality in medium-voltage...
Info Letter No. 8: Apparent Power and Reactive Power in Three-Phase Networks
The range of electromechanical and electronic measuring devices in analog - and digital technology...
Info Letter No. 5: Zero Sequence Voltage in Three-Phase Networks
With balanced network operation and inequality of the impedances in the consumer circuit, the phase...
Info Letter No. 4: Summation of Alternating Currents
For the parallel connection of power sources, the principle of superposition applies, when all resources...
Info Letter No. 2: Measurement Transformers in Three-Phase Networks (Part 2)
In a symmetrically loaded three-wire three-phase network, a two-pole insulated voltage transformer...
Info Letter No. 1: Measurement Transformers in Three-Phase Networks (Part 1)
The direct connection of measuring devices into the network is limited for safety reasons to values...
Simultaneous Charging of Electric Vehicles
The Technische Hochschule Bingen (THB) charged e-vehicles in parallel at ten charging points. What was of interest here was measuring the charging current and its effect on the THB network; to determine pulse frequencies and their distribution across the network and to assess network asymmetries...
Evaluating Supraharmonics up to 150 kHz in E-Vehicles at TH Bingen
In the first part of the measurement campaign in 2016, various e-vehicles were assessed as to their charging behaviour and feedback to the network. The evaluation considered DC harmonics up to the 50th...
Power Quality Under the Microscope
The transition in the generator and consumer structure of Central European electrical grids is in full swing...
Power Quality Detectives in the Low-Voltage Grid
Modern measurement technology makes an important contribution to the power quality of low-voltage networks. Without it, we could not make statements about the quality of individual power characteristics, nor find the causes of faults. It was for this reason that the decision was taken in early 2001...
Emergency Power Supplies in Hospitals and Data Centres
According to DIN VDE 0100 part 710, if the voltage over one or more external cables providing the general power supply to a hospital falls to less than 90% of the nominal grid voltage for a period of more than 0.5s, the power supply must be