Low-voltage feeder monitoring for power grids and industry

Reliably monitor transformer loading and outgoing feeders

Open Standard Interfaces - Easy Integration into Existing Systems
IT Security by Design - Protecting Your Data and Infrastructure from the Start
End-to-End Data Flow - From Field-Level Measurement to Analysis and Higher-Level Systems
Patch & Device Management - Centralized Administration and Secure Device Updates
Open Standard Interfaces - Easy Integration into Existing Systems
IT Security by Design - Protecting Your Data and Infrastructure from the Start
End-to-End Data Flow - From Field-Level Measurement to Analysis and Higher-Level Systems
Patch & Device Management - Centralized Administration and Secure Device Updates

Growing numbers of photovoltaic (PV) systems, electric vehicle (EV) chargers, battery energy storage systems (BESS), heat pumps, and changing industrial loads make low-voltage (LV) networks increasingly dynamic, while many secondary substations and industrial LV distribution systems still lack feeder-level visibility. The A. Eberle LV feeder monitoring solution provides reliable measurement data to assess loading, available capacity, power flows, and load distribution across utility and industrial power networks.

Typical applications:

  • Feeder measurement in secondary substations and industrial LV distribution systems
  • New secondary substations: »PQI-LV« as the head device, with feeder data integrated via NH strip-type fuse-switch-disconnectors from established manufacturers, e.g. Jean Müller
  • Retrofit and industrial LV distribution: »P-Sense« + »V-Sense« + an A. Eberle power quality (PQ) measurement device
  • Production lines, peak load and capacity monitoring, data centers, PV, BESS, EV charging and uninterruptible power supply (UPS) systems
  • Provision of measurement data for monitoring, analysis, and further processing

This solution is suitable, if:

  • A consistent feeder measurement solution is required for utility or industrial LV networks
  • Individual feeders need to be systematically measured and evaluated
  • Peak load contributors, available electrical capacity or potential overloads need to be identified
  • Existing switchgear needs to be digitalized and monitored without being replaced
  • Measurement data needs to be stored locally and reliably transferred to higher-level systems

LV Feeder Monitoring for Utility and Industrial Applications

Flexible Measurement Concepts for New Installations, Retrofit and Industry

The A. Eberle LV feeder monitoring solution supports different feeder monitoring concepts depending on the installation. In new secondary substations, »PQI-LV« integrates feeder data via Modbus RTU from NH strip-type fuse-switch-disconnectors. For retrofit projects and industrial LV distribution, »P-Sense« and »V-Sense« are combined with an A. Eberle PQ measurement device. The result is a scalable solution for feeder transparency, local data storage, and data transfer via open interfaces.

Further questions or want to start an enquiry? Please click “Product Enquiry”.

LV Feeder Power Measurement in Secondary Substations
LV Feeder Power Measurement in Industrial Distribution Systems

Measure. Regulate. Across All Grids.

A. Eberle GmbH & Co. KG, founded in 1980 and headquartered in Nuremberg, Germany, operates in the field of measurement and regulation technology for the energy sector as well as for medium-sized and large industrial companies. Our products and services ensure and enhance the availability of energy supply across all voltage levels and support the integration of renewable energy sources into power grids.

Logos: TÜV Rheinland, TOP 100 and kununu Top Company

Cross-Product Downloads

Special Publications
Flyer
Product Overview A. Eberle
A. Eberle Seminars in Nuremberg

PQI-LV

Instruction Manual
Installation Manual
Technical Data Sheets
Release Notes
Firmware
Interface Lists
Accessories
WinPQ Lite
Certificates
Tender Specification

WebPQ®

(for fixed installed measuring devices: PQI-DE, PQI-DA smart, PQI-LV)

Flyer
Instruction Manual
Software
PostgreSQL - Updates (Patches)
PostgreSQL - Migration
Release Notes
System Requirements
Software Licensing - General Provisions
Security Advisories
Tender Specification

Accessories

I-Sense: Current Feeder Measurement
Mounting Panel
Rogowski Coil
Current Clamp
Divisible Differential Current Transformer
GPS Receiver Set
Modem / Remote Connection

The Complete Solution for LV Feeder Monitoring in Utility and Industrial Power Networks

Reliable Data for Transformer and LV Feeder Loading and Capacity Assessment

Reliable measurement data is essential for assessing the actual loading of transformers and individual LV feeders, identifying available capacity and supporting operational decisions. The solution provides a consistent data basis for monitoring, analysis and planning across utility and industrial power networks.

Secondary substation with PQI-LV, V-Sense and P-Sense for LV feeder monitoring
PQI-LV measurement device

»PQI-LV« - The Central Device for LV Feeder Monitoring

»PQI-LV« serves as the central device for acquiring, processing, storing, and providing measurement data in the secondary substation. It combines its own voltage and current measurements with feeder data integrated via Modbus RTU. Depending on the installation, feeder data is provided by NH strip-type fuse-switch-disconnectors or by »V-Sense« and »P-Sense«. Measurement data can be stored locally and transferred to higher-level systems via various supported communication protocols.

»V-Sense« - Central Voltage Sensor

In secondary substations and industrial LV distribution systems, »V-Sense« provides the central voltage measurement for the connected »P-Sense« devices. It supplies the P-Sense bus with 24 V DC and simultaneously transfers the measured voltage values via galvanically isolated outputs.

V-Sense voltage sensor
P-Sense current and power measurement device

»P-Sense« - Current and Power Measurement per LV Feeder

»P-Sense« measures the currents of individual outgoing LV feeders using Rogowski coils. It continuously measures AC currents from 1 A to 1,600 A with a frequency bandwidth of up to 3 kHz. In combination with »V-Sense«, active power, reactive power, and cos φ are available per feeder, providing valuable data for load, capacity and energy monitoring.

Open Data Interfaces for Integration into Existing Systems

The A. Eberle LV feeder monitoring solution enables flexible provision of measurement data centrally via the WebPQ® platform using a REST API or decentrally directly via the measurement devices as RTUs. In the decentralized approach, the devices provide data via MQTT or IEC 60870-5-104, enabling integration into SCADA systems, energy management systems, and applications for grid state assessment or grid calculation.

The modular architecture simplifies integration into secondary substations, industrial LV distribution systems, and existing switchgear configurations.

V-Sense installed in switchgear

LV Feeder Monitoring in New and Existing Installations

Different measurement concepts are available depending on the installation and application.


In new secondary substations, »PQI-LV« is integrated via Modbus RTU with NH strip-type fuse-switch-disconnectors from established manufacturers, such as Jean Müller. Additional sensors and third-party components can also be integrated via Modbus RTU.

PQI-LV with NH strip-type fuse-switch-disconnectors via Modbus RTU

For retrofit projects and industrial LV distribution, »P-Sense« is combined with »V-Sense« and an A. Eberle PQ measurement device. Using Rogowski coils, the concept enables flexible feeder monitoring and digitalization of existing switchgear without replacing the installation.

PQI-LV with V-Sense and P-Sense for retrofit LV feeder monitoring

Real World Example: Full LV Feeder Visibility in an Existing Secondary Substation


Retrofitted feeder measurement in an existing secondary substation
Rogowski coils installed for current measurement on LV feeders

More visibility without touching the existing switchgear: in this secondary substation, feeder monitoring was retrofitted with »PQI-LV«, »V-Sense« and »P-Sense«. »P-Sense« captures the current of every individual LV feeder via Rogowski coils, »V-Sense« delivers the central voltage measurement, and »PQI-LV« brings it all together - collecting, storing and processing the data as the foundation for further analysis.

The transformer main infeed benefits too: it's measured to power quality Class A (IEC 61000-4-30), with optional disturbance recording available as a retrofit. Current sensing at the transformer is flexible - Rogowski coils, or standard mV signals where conventional current transformers (CTs) are already in place. And since »PQI-LV« doubles as an MQTT gateway, there's no need for extra gateway hardware - a real cost advantage.

The result: a reliable, structured data foundation for every feeder and the true grid situation - with zero disruption to the existing switchgear. The same concept works just as well in industrial LV main and sub-distribution systems.

  • Application: Retrofit of an existing secondary substation - no switchgear replacement
  • Measurement: Current and power per LV feeder, plus transformer main measurement in PQ Class A with optional disturbance recording
  • Flexibility: Current sensing via Rogowski coils or mV signals from conventional CTs
  • Cost advantage: »PQI-LV« as an integrated MQTT gateway - no extra hardware required
  • Customer benefit: Full feeder-level transparency as the basis for load and capacity assessment, and further data processing
  • Also applicable to: Industrial LV main and sub-distribution systems

IT Security by Design for Utility and Industrial LV Systems

The measurement solution with »PQI-LV« as the central device provides IT security features including audit logging, encryption technologies, and User Rights Management (URM) with Role Based Access Control (RBAC).

PQI-LV IT security features: audit logging, encryption and user rights management

WebPQ® - Central Platform for LV Feeder Monitoring

WebPQ®

Central Analysis of LV Measurement Data

WebPQ® is the central analysis platform for evaluating and providing measurement data from secondary substations and industrial LV distribution systems. It enables structured analysis, visualization, alarming, reporting, and further processing of measurement data across individual installations and larger device fleets. WebPQ® is available for on-premises operation and as a SaaS solution.

Do You Have Any Further Questions About
LV Feeder Monitoring?

Our Specialists Will Be Happy to Help You!


Contact Us

News From the Product Group

PQSys - News

Blogpost

Year 2038 Problem: Industrial Systems

22. October 2026

Year 2038: Why early assessment matters The Year 2038 problem can affect industrial systems that store Unix time as a […][...]

Read more

General Knowledge

Data Centre Power Quality Monitoring and Voltage Regulation

22. October 2026

Read more

Blogpost

PQ-Box ONE giveaway

13. October 2026

Take part and win a PQ-Box ONE! As part of our PQ-Box Trade-In Campaign, you also have the chance to […][...]

Read more

Blogpost

PQ-Box Trade-in Promotion: Only From October 1 to December 31 2026

1. October 2026

For a limited time: Receive a discount for the trade-in of your PQ-Box 100 or a comparable external old device (3-phase power quality analyser). Click here for further information![...]

Read more

General Knowledge

IEC TR 61850-90-17: Power Quality, PQDIF and WebPQ®

10. August 2026

Read more

Blogpost

GRUNDIG AKADEMIE visits A. Eberle

7. August 2026

In 2026, the GRUNDIG AKADEMIE Nuremberg visited A. Eberle with a group of trainee technicians. During the visit, the participants gained an insight into our company, technical fields of work and potential[...]

Read more

Blogpost

A. Eberle named one of the TOP 100 Innovators for 2026

22. July 2026

As part of the 2026 TOP 100 Awards, we had the honour of receiving a special accolade in Heidelberg last week – presented in person by Christian Wulff, former Federal President and mentor of the TOP[...]

Read more

General Knowledge

Digital Substation

17. June 2026

A digital secondary substation combines measurement, fault location and secure data analysis to improve transparency across medium- and low-voltage distribution grids.[...]

Read more

Blogpost

International Partner Week 2026 - Exchange, knowledge transfer and collaboration in Nuremberg

1. June 2026

We were delighted to welcome our international partners to Partner Week 2026. The chance to chat in person, seeing familiar faces and making new acquaintances made the week a special one for us.[...]

Read more

Webinar

»PQSys« Webinar: PQ-Monitoring & Feeder Current Measurement in Low-Voltage Grids 4

28. May 2026

Webinar recording from 2026-05-13: »PQSys - PQ-Monitoring & Feeder Current Measurement in Low-Voltage Grids - part 4«. [...]

Read more

General Knowledge

Measuring Equipotential Bonding

13. May 2026

Measuring equipotential bonding is essential for verifying low-resistance, continuous connections between conductive parts. This article explains equipotential bonding, relevant standards, typical measurement[...]

Read more

General Knowledge

Insulation Resistance and Insulation Measurement

30. April 2026

Insulation measurement helps assess the safety and condition of electrical installations. This article explains insulation resistance measurement, relevant limits, test voltages and practical interpretation[...]

Read more

Blogpost

A. Eberle and Bregal Unternehmerkapital enter into a growth partnership

14. April 2026

A. Eberle and Bregal enter into a growth partnership. The partnership with BU is intended to accelerate A. Eberle’s international expansion, innovation and technological advancement.[...]

Read more

General Knowledge

Power Plant Controller: Measurement Values at the Grid Connection Point

26. March 2026

Power Plant Controller operation at the grid connection point depends on low-latency, accurate, and dynamically reliable measurement values. This article explains the technical requirements, the role of[...]

Read more

General Knowledge

Measuring Harmonics: Detecting Disturbances in Buildings

6. March 2026

Harmonic distortion and supraharmonics can cause flicker, nuisance tripping and device malfunctions in modern buildings. This article explains how to measure harmonics at the socket outlet and interpret[...]

Read more

Blogpost

Power Quality Monitoring for Electrical Contractors - Mobile Network Quality Measurement with the PQ-Box ONE

2. March 2026

How a portable power quality analyzer like the PQ-Box ONE helps electrical professionals identify voltage disturbances, improve documentation and make reliable technical decisions.[...]

Read more

Blogpost

Power Quality Monitoring: Risks of Poor Power Quality

18. December 2025

Power quality monitoring translates “invisible” disturbances into measurable causes and KPI impacts. This guide explains common power-quality events and a practical workflow to measure, evaluate and[...]

Read more

Webinar

»Cyber Security« Webinar: A Challenge for European Energy Companies

3. December 2025

Webinar recording from 2025-11-26: »Cyber Security« - A Challenge for European Energy Companies[...]

Read more

Blogpost

A. Eberle at the Schwabach City Run 2025

24. November 2025

A. Eberle was represented by 37 participants at the 2025 Schwabach City Run, setting a new internal record for participation. Particularly noteworthy is Benjamin Rentsch's first place in the M 35 40 age[...]

Read more

General Knowledge

Total Harmonic Distortion (THD) in Low Voltage Networks

20. November 2025

This study examines harmonic distortion in modern low-voltage grids, showing real measurement data, key standards (EN 50160, IEC 61000-3-2/-4-30) and practical ways to reduce THD in applications such as[...]

Read more

Contact request:



* Mandatory

Your data is being processed

a-eberle kontakt newsletter ×

You are interested in %s:

Would you like to receive more interesting content such as technical reports, application examples, and training videos on the topic of %s?

Register here free of charge:

Thank you for subscribing to the %s newsletter.

The download started automatically in a new window.

How did you hear about us?
Consent to data transfer*

* Mandatory fields