MCI - Multi-Frequency Current Injection for Low or Highly Variable Displacement Voltages

For reliable tuning of compensated, highly symmetrical grids

steuerung
Compact dimensions, no inductors and no additional voltage transformer necessary
Simulation-Messwerte-Prozesswerte
Can be deployed for 20 kV networks to 1300 A Ice
steuerung
IO cabling to MCI also possible incl. emergency positioning
erdschluss-kompensieren
Includes automatic power reduction
steuerung
Compact dimensions, no inductors and no additional voltage transformer necessary
Simulation-Messwerte-Prozesswerte
Can be deployed for 20 kV networks to 1300 A Ice
steuerung
IO cabling to MCI also possible incl. emergency positioning
erdschluss-kompensieren
Includes automatic power reduction

The current injection system can be retrofitted at any time and provides a space-saving solution for low or highly fluctuating displacement voltages. It supports reliable grid operation and prevents unnecessary wear of the arc suppression coil.

Typical application:

  • Compensated grids with central and/or decentralised arc suppression coils
  • Low or highly fluctuating displacement voltages, particularly in highly symmetrical grids
  • Can be retrofitted at any time to an existing REG-DP or REG-DPA

This device is suitable if:

  • Conventional control by “moving the coil” no longer delivers reliable results
  • The displacement voltage is below 0.5% and may be strongly influenced by fluctuating loads or external grids
  • The arc suppression coil has an integrated power auxiliary winding

Multi-Frequency Current Injection

MCI

The classic regulation process, i.e. searching for the resonance curve across the range of travel of the coil, can no longer successfully adjust the arc suppression coil in certain network situations. We have developed this multi-frequency current injection for the increasingly frequent cases where the zero-sequence voltage is highly disturbed or subject to extreme influences or where networks are highly symmetrical. The current injection creates a signal that is fed into the network via the auxiliary power winding of the arc suppression coil. From the network reaction, the combined REG-DP(A) and current injection are able to calculate a resonance curve despite the low or highly variable zero-sequence voltage.

Further questions or want to start an enquiry? Please click “Product Enquiry”.

Substations (HS/MS)
Transmission & distribution grids (HS/MS)
Industrial plants & production facilities
Hydroelectric power plants

Measure. Regulate. Across All Grids.

A. Eberle GmbH & Co. KG, founded in 1980 and headquartered in Nuremberg, Germany, operates in the field of measurement and regulation technology for the energy sector as well as for medium-sized and large industrial companies. Our products and services ensure and enhance the availability of energy supply across all voltage levels and support the integration of renewable energy sources into power grids.

Compact Dimensions, No Inductors and No Additional Voltage Transformer Necessary

Thanks to the multi-frequency current injection's compact form, it can fit into any existing control cabinet. During operation, up to eight different frequencies can be fed in directly via the auxiliary power winding of the suppression coil, i.e. without additional inductors, as required by other current injections. In addition, the MCI is able to both feed in power via the auxiliary power winding AND measure the zero-sequence voltage, without the feed negatively affecting the measurement. There is no need for zero-sequence voltage measurements to be decoupled from the e-coil.

multi-frequency-current-injection

Can Be Deployed for 20 kV Networks to 1300 A Ice

The multi-frequency current injection MCI can be used in 20 kV networks with average damping at up to 1300 A (capacitive earth current). The MCI can also be used in networks with lower or higher nominal voltages, whereby the maximum capacitive earth current will change in indirect proportion.

Includes Automatic Power Reduction

The multi-frequency current injection MCI can be used in 20 kV networks with average damping and up to 1300 A (capacitive earth current). For very small networks, the current injection can lead to undesirably strong influences on the zero-sequence voltage, meaning in the worst-case scenario that the earth fault threshold may be crossed. To prevent this, the MCI monitors influences on the zero-sequence voltage and reduces them as needed automatically. The MCI can also be used in networks with lower or higher nominal voltages, whereby the maximum capacitive earth current will change in indirect proportion.

multi-frequency-current-injection

IO Cabling to MCI Also Possible Incl. Emergency Positioning

To simplify the cabling between the REG-DP(A), the MCI and suppression coil, the I/O signals (peak/trough commands, limit switch, potentiometer) can be wired directly to the MCI. In this case, only the communication needs to be cabled between REG-DP(A) and MCI (“Mode 1”). If the communications line between REG-DP(A) and MCI fails, the MCI can carry out emergency positioning.

multi-frequency-current-injection

Parametrisation Control and Connection via REG-DP(A)

By connecting the MCI unit to the REG-DP(A) regulator, the MCI can be parameterised, calibrated and controlled. Connection via all standard communications protocols is also possible. The REG-DP(A) regulator can be connected via REG-P, REG-PE or REG-PEDSV control units. The following protocols are available (further protocols on request):

  • IEC 60870 -5 -101 / 103 / 104
  • IEC 61850
  • DNP 3.0 RTU / DNP 3.0 TCP
  • MODBUS RTU / MODBUS TCP
  • SPABUS

Do You Have Questions About
Multi-Frequency Power Feed?

Our Specialists Will Be Happy to Help You!


Contact Us

AE Toolbox
The perfect supplement to arc suppression devices: freely adjustable project planning and parameterisation software

The AEToolbox works on a project basis and impresses with its range of functions and the versatility that the program offers.

News From the Product Group

EORSys - News

Blogpost

GRUNDIG AKADEMIE visits A. Eberle

7. August 2026

In 2026, the GRUNDIG AKADEMIE Nuremberg visited A. Eberle with a group of trainee technicians. During the visit, the participants gained an insight into our company, technical fields of work and potential[...]

Read more

Webinar

»EORSys« Webinar: Integration of Future-Proof Secondary Substations Into the Distribution Grid - Part 2 | A. Eberle

27. July 2026

Webinar recording from 2026-07-15: »EORSys« -Integration of Future-Proof Secondary Substations Into the Distribution Grid with EOR-1DS & EOR-3DS - Part 2[...]

Read more

Blogpost

A. Eberle named one of the TOP 100 Innovators for 2026

22. July 2026

As part of the 2026 TOP 100 Awards, we had the honour of receiving a special accolade in Heidelberg last week – presented in person by Christian Wulff, former Federal President and mentor of the TOP[...]

Read more

General Knowledge

Digital Substation

17. June 2026

A digital secondary substation combines measurement, fault location and secure data analysis to improve transparency across medium- and low-voltage distribution grids.[...]

Read more

Blogpost

International Partner Week 2026 - Exchange, knowledge transfer and collaboration in Nuremberg

1. June 2026

We were delighted to welcome our international partners to Partner Week 2026. The chance to chat in person, seeing familiar faces and making new acquaintances made the week a special one for us.[...]

Read more

Blogpost

A. Eberle and Bregal Unternehmerkapital enter into a growth partnership

14. April 2026

A. Eberle and Bregal enter into a growth partnership. The partnership with BU is intended to accelerate A. Eberle’s international expansion, innovation and technological advancement.[...]

Read more

Webinar

»Cyber Security« Webinar: A Challenge for European Energy Companies

3. December 2025

Webinar recording from 2025-11-26: »Cyber Security« - A Challenge for European Energy Companies[...]

Read more

Blogpost

A. Eberle at the Schwabach City Run 2025

24. November 2025

A. Eberle was represented by 37 participants at the 2025 Schwabach City Run, setting a new internal record for participation. Particularly noteworthy is Benjamin Rentsch's first place in the M 35 40 age[...]

Read more

Webinar

»EORSys« Webinar: Integration of Future-Proof Secondary Substations Into the Distribution Grid - Part 1 | A. Eberle

15. October 2025

Webinar recording from 2025-10-15: »EORSys« -Integration of Future-Proof Secondary Substations Into the Distribution Grid with EOR-1DS & EOR-3DS - Part 1[...]

Read more

General Knowledge

Power in Multiphase Systems

7. August 2025

This technical report highlights the special features of power transmission in three-phase systems and offers valuable insights into the optimisation and analysis of modern power grids.[...]

Read more

Webinar

»EORSys« Webinar: EOR-1DS - the Economical Fault Indicator for the Secondary Substation

22. July 2025

Webinar recording from 2025-07-16: »EORSys - EOR-1DS - the Economical Fault Indicator for the Secondary Substation«. [...]

Read more

Blogpost

Visit From the Rudolf Diesel Technical School at A. Eberle

15. July 2025

We were happy to welcome you, Rudolf-Diesel-Fachschule! Yesterday, we had the pleasure of welcoming two classes of future electrical engineering technicians from the Rudolf-Diesel-Fachschule Nürnberg[...]

Read more

Blogpost

TOP 100 Awards 2025: Innovation for the Energy Future

15. July 2025

💡 As part of the TOP 100 Awards 2025, we were honored to receive a special recognition last week in Mainz – personally presented by TV host and science journalist Ranga Yogeshwar.[...]

Read more

Blogpost

University Excursion: Pentecost Excursion of the Friedrich-Alexander-University Erlangen-Nuremberg (FAU)

14. July 2025

As a company dedicated to innovation, education, and the energy transition, we are pleased to have once again supported the Whitsun excursion of Friedrich-Alexander University Erlangen-Nuremberg (FAU)[...]

Read more

Blogpost

Further Growth at A. Eberle

14. July 2025

Welcome to the team! We welcome our new colleagues at A. Eberle.[...]

Read more

Product innovation

Product Discontinuation: Power Quality Interface (PQI-D) as of 31.12.2026

27. March 2025

The Power Quality Interface (PQI-D) product can only be ordered up to and including 31 December 2026.[...]

Read more

Product innovation

Product Discontinuation: Earth Fault Locating Relay (EOR-D) as of 31.12.2026

27. March 2025

The product earth fault locating relay for multiple outgoing circuits (EOR-D) can only be ordered up to and including December 31st, 2026.[...]

Read more

Webinar

»EORSys« Webinar: Digital Secondary Substations in the Distribution Grid of the Future

16. September 2024

Webinar recording from 2024-05-07: »EORSys - Digital Secondary Substations in the Distribution Grid of the Future«. [...]

Read more

Blogpost

International Partner Week 2024 - a Look Back

29. August 2024

Our International Partner Week 2024 - many old friends and new faces were our guests, it was a pleasure.[...]

Read more

Webinar

»EORSys« Webinar: Future-Proof Integration of Digital Substations in the Distribution Grid

15. July 2024

Webinar recording from 2024-07-11: »EORSys - Future-proof Integration of Digital Substations in the Distribution Grid«. [...]

Read more

Contact request:



* Mandatory

Your data is being processed

a-eberle kontakt newsletter ×

The download started automatically in a new window.

How did you hear about us?
Consent to data transfer*

* Mandatory fields