Harmonization of the Database of Reports and All Related Interfaces
The WinPQ V6.0 is a new major release. An update to the version transfers the existing database into a harmonized and future-proof database schema. This is a necessary and major step to ensure future-oriented developments with a high backward compatibility in future versions with many open interfaces and new user interfaces.
Furthermore, we would be happy to provide you with a corresponding service offer for the major update directly. Please do not hesitate to contact us: vertrieb@a-eberle.de
In Addition to Harmonization, Other Important and Future-Oriented Features Have Been Added:
- IEEE519 (2014) report added / template for PQI-DE / PQI-DA smart added in WinPQ lite
- Added performance of harmonics
- Detection of fault direction in fault records (output before / after measuring point) via Transnostic calculation methodology for all fault records of PQI-DA smart and PQI-DE’s added
- DRAG & DROP for measurement types in visualization added
- Group selection of measurands / Predefined measurand groups for easy and fast evaluation and visualization
- Full support of the PQI-DE: (1) Display of differential current (thresholds: warning and alarm) & temperature events and (2) Binary inputs
- Email dispatch possible for messages from system status
- Counting of EN50160 events in all reports (unbalance and long-term flicker)
- Load characteristics via reporting
- Update process simplified – updates are stored completely in the database for easy client updates
- Comtrade import with mapping via measured variables DB
- Explanations and definitions added for all PQ events
- Suppression of range violation RMS value from PQI-DA smart / PQI-DE as active event
- Comtrade display and import functions, especially for retrofit solutions, a simple and reliable solution for old disturbance recorders during a system changeover
- Heatmap display of all frequency ranges from 50Hz – 150kHz (Also supports PQ-Box 300 data up to 150kHz)
You will find more information about the software in our Release Notes.
New Features for the WinPQ Lite 6.0:
- Connection to the device is closed automatically when the user is inactive (default value = 10min)
- Online values of the residual current measurement variables
- Online values of binary inputs
- Addition of prefixes of measurement units for power and energy in WinPQ lite
- Display of status of connections for IEC61850 communication visible in device status
- Parameterization of time settings now also directly in UTC (coordinated universal time) possible
- French user manual has been added
- Added ripple control group designations
- Added summer/winter time of trigger criterion in recorder treeview
- Calibration with SSH
Security-Related Updates and Features:
- [WinPQ lite] Update the components of SSH communication
- [WinPQ lite] support setup and beat drive RADIUS protocol with PQI-DA smart and -DE
- New component for encrypted database communication (client / server) with TLS 1.2 (only with MySQL database)
- New SSH module for improved secure connection and communication with PQ devices
- IMPORTANT: Hashes of the fingerprints of the devices must be reconfirmed in the online data!