Emergency Power Supplies in Hospitals and Data Centres.

Experts are in demand.

According to DIN VDE 0100 part 710, if the voltage over one or more external cables providing the general power supply to a hospital falls to less than 90% of the nominal grid voltage for a period of more than 0.5s, the power supply must be switched for safety. Looking in the direction of energy flow, this switching has to take place at the main distribution board level, behind the feed transformers and power sources. To ensure safety, it has to guarantee that the electrical systems can be connected within 15s to a secure power source providing energy for 24 hours. Reduction of the operational period from 24 hours to 3 is only permissible if the medical treatment and inspection of patients can be safely ended within this period and the hospital evacuated.

Summary

Only proper project planning and quality-assured measurement prevent nasty surprises. The required measurement technology has to fulfil diverse requirements. Voltages, currents, power and frequency must be recorded at a high resolution of 10 ms. An average measured over 200ms or one second would not be able to detect these network fluctuations. Deviations from the sinusoidal wave and voltage transients can be recorded using oscilloscopes. Using various trigger options such as a sine envelope curve trigger can provide even more information on the fault.

Our range for problem-solving

The mobile network analyzers by A. Eberle GmbH & Co. KG, Nuremberg, fulfil all these requirements. These record and evaluate over 2,200 measurement values in parallel. These measurement devices are particularly suitable for mobile use thanks to their robust design and simple means of operation. Built-in network analyzers and fault recorders are perfectly suited for permanent monitoring at a notable network point.

Do you need further information?

Feel free to contact us!


Contact

You might also be interested in

Cost efficient management of digital secondary substations: Earth fault indicator EOR-3DS as digitisation unit for secondary substations

Digital secondary substations are becoming a key element for distribution system operators in terms of automation, monitoring, and efficient operations of their networks Read this technical report about the EOR-3DS in its role as digitisation unit for secondary substations

Read more

Angle determination of voltage and current harmonics in practice

Tracking down causes of harmonics in the energy grid in practice Today, there are hardly any consumers that draw a […]

Read more

All „Supra“ with your grid?

Today's devices and equipment such as switched-mode power supplies, frequency converters, controlled drives, charging devices for e-mobiles or LED lighting work internally with high clock frequencies in order to regulate power efficiently. These can lead to line-borne as well as field-borne (coupled) interference in the power grid. In this technical report, we explain how you can detect these sources of interference in the grid using suitable measurement technology.

Read more

Power Quality Analysis: Tips and Tricks II

Useful tips & tricks for handling Power Quality measuring devices and typical user errors - now in our two-part article! This article provides further insights and practical tips and application examples for power quality analysis.

Read more

Contact request:



Your data is being processed

a-eberle kontakt newsletter ×

Our seminars &
webinars

► Register here!

x