Smart Grid

Smart grids

What is a smart grid/intelligent electricity network?

A smart grid, also known as an intelligent power grid, is a highly developed energy network that improves traditional power grids using modern technologies and intelligent communication systems. These networks enable more efficient and flexible energy distribution as well as the active participation of end consumers. The official definition comes from the International Energy Agency (IEA), which describes a smart grid as “a network that enables the two-way flow of energy and information between the power plant and the consumer”.

An example of a smart grid application is the ability to charge electric vehicles when the price of electricity is low or to integrate renewable energy sources such as solar energy and wind power into the network when they are available.

The idea of smart grids emerged in the 1990s as the need for more efficient energy management and the integration of renewable energy became more apparent. Since then, numerous developments and technologies have made smart grids an important component of modern energy infrastructure.

What technology is behind smart grids/intelligent power grids?

The technology behind smart grids comprises various components and systems that together ensure that intelligent and efficient energy management is possible:

  1. Smart metering systems: These systems record energy consumption in real time and enable consumers to control their energy costs.
  2. Automation and control: This includes advanced sensor technologies that can monitor the status of the power grid and respond automatically to minimize power outages.
  3. Communication networks: High-speed communication networks are an essential component, enabling the various elements of the smart grid to communicate with each other and exchange data in real time.
  4. Renewable energies and storage technologies: The integration of renewable energy sources such as solar and wind power into the network requires special technologies for controlling and storing energy.
  5. Security: Installed measurement and control technology must correspond to the current state of the art in the field of IT security and must also be safe to use in the future thanks to the possibility of patch and device management.
  6. Data analysis and software: Advanced software solutions process the collected data to recognize patterns, create forecasts and make decisions in real time.

A. Eberle technology in the smart grid

Ready today for tomorrow

A. Eberle map Smart Grid A. Eberle E-Mobility as consumer and feeder / storage system Smart Grid A. Eberle Smart Households with PV and heat pumps Smart Grid A. Eberle Industrial companies with own energy supply Smart Grid A. Eberle Solar Parks A. Eberle Transmission and distribution Grids A. Eberle Data grid Smart Grid A. Eberle Central data center A. Eberle fossil power plants A. Eberle Windmills

Transmission and distribution grids

  • A-Eberle EOR-3DS
    EOR-3DS
    The freely programmable earth fault and short-circuit indicator
    learn more
  • A-Eberle EOR-1DS
    EOR-1DS
    The earth fault and short-circuit indicator for in-depth location across the network
    learn more
  • A-Eberle PQI-DE
    PQI-DE
    The Tool for Power-Quality-Experts
    learn more
  • A-Eberle REGSys
    REGSys
    Monitor. Register. Control.
    learn more
  • A-Eberle PQ-Box 200
    PQ-Box 200
    The mobile tool for the expert
    learn more

Wind farms

  • A-Eberle EOR-3DS
    EOR-3DS
    The freely programmable earth fault and short-circuit indicator
    learn more
  • A-Eberle PQ-Box 200
    PQ-Box 200
    The mobile tool for the expert
    learn more
  • A-Eberle PQI-DA smart
    PQI-DA smart
    The Power Quality Allrounder
    learn more
  • A-Eberle PQI-DE
    PQI-DE
    The Tool for Power-Quality-Experts
    learn more
  • A-Eberle PQ-Box 300
    PQ-Box 300
    The Tool for High Frequency Ranges
    learn more

Photovoltaic park

  • A-Eberle EOR-3DS
    EOR-3DS
    The freely programmable earth fault and short-circuit indicator
    learn more
  • A-Eberle PQ-Box 300
    PQ-Box 300
    The Tool for High Frequency Ranges
    learn more
  • A-Eberle PQI-DA smart
    PQI-DA smart
    The Power Quality Allrounder
    learn more
  • A-Eberle REG-DA
    REG-DA
    Regulate, monitor, register, control
    learn more
  • A-Eberle LVRSys
    LVRSys
    Low Voltage Regulation System
    learn more
  • A-Eberle EOR-1DS
    EOR-1DS
    The earth fault and short-circuit indicator for in-depth location across the network
    learn more

Fossil power plants

  • A-Eberle REGSys
    REGSys
    Monitor. Register. Control.
    learn more
  • A-Eberle PQ-Box 200
    PQ-Box 200
    The mobile tool for the expert
    learn more
  • A-Eberle PQI-DE
    PQI-DE
    The Tool for Power-Quality-Experts
    learn more
  • A-Eberle REG-DA
    REG-DA
    Regulate, monitor, register, control
    learn more
  • A-Eberle PQI-DA smart
    PQI-DA smart
    The Power Quality Allrounder
    learn more
  • A-Eberle PQ-Box 300
    PQ-Box 300
    The Tool for High Frequency Ranges
    learn more

Industrial location

  • A-Eberle PQ Box 300
    PQ-Box 300
    The Tool for High Frequency Ranges
    learn more
  • A-Eberle REG-DA
    REG-DA
    Regulate, monitor, register, control
    learn more
  • A-Eberle LVRSys
    LVRSys
    Low Voltage Regulation System
    learn more
  • A-Eberle REG-DPA
    REG-DP(A)
    The arc suppression coil regulator in an IP54 housing
    learn more
  • A-Eberle Stromeinspeisung
    Power feed
    Solutions for different network topologies
    learn more
  • A-Eberle PQI-DE
    PQI-DE
    The Tool for Power-Quality-Experts
    learn more

Energy saving house

  • A-Eberle PQ-Box 200
    PQ-Box 200
    The mobile tool for the expert
    learn more
  • A-Eberle PQI-DA smart
    PQI-DA smart
    The Power Quality Allrounder
    learn more
  • A-Eberle PQ-Box 50
    PQ-Box 50
    The Universal Network Analyser
    learn more
  • A-Eberle PQ-Box 150
    PQ-Box 150
    The mobile Power Quality Allrounder
    learn more
  • A-Eberle PQ-Box 300
    PQ-Box 300
    The Tool for High Frequency Ranges
    learn more

E-Mobility

  • A-Eberle PQ-Box 50
    PQ-Box 50
    The Universal Network Analyser
    learn more
  • A-Eberle PQI-DA smart
    PQI-DA smart
    The Power Quality Allrounder
    learn more
  • A-Eberle PQ-Box 300
    PQ-Box 300
    The Tool for High Frequency Ranges
    learn more
  • A-Eberle LVRSys
    LVRSys
    Low Voltage Regulation System
    learn more
  • A-Eberle PQ-Box 150
    PQ-Box 150
    The mobile Power Quality Allrounder
    learn more
  • A-Eberle PQ-Box 200
    PQ-Box 200
    The mobile tool for the expert
    learn more
differenzstrommessung-differenzstrom-messgeraet

Network analysis in the smart grid

Today & tomorrow with PQSys

The PQI-DA smart & PQI-DE products are the latest generation of our permanently installed power quality and grid analysis devices with fault recorder function. Particularly in conjunction with the new I-Sense technology, which enables current outflow measurement for up to 16 outgoing circuits in the low voltage, our measurement technology increases transparency in the low voltage grid.

The solution is open for intelligent current sensors via Modbus RTU or other third-party devices such as temperature sensors. In conjunction with the WebPQ™ software and open interfaces, this further contributes to increasing transparency in the low-voltage grid.

In addition, the solution protects the local substation from negative effects by recording all relevant measurement data in the range of EN50160 measured variables, from supraharmonics to high-resolution fault records to secure the burden of proof in the event of an incident.

In the field of IT security, the PQI-DA smart and PQI-DE power quality measuring devices follow the motto “Security by Design” right from the development stage and are based on state-of-the-art technology:

LVRSys™ low-voltage regulation system

The system for integrating e-mobility, PV systems and heat pumps into the grid

The transformation of the low-voltage grid, driven by the rapid increase in the integration of e-mobility, photovoltaics and – most recently – heat pumps, poses major challenges for grid operators and energy suppliers. A particular challenge in this context is posed by voltage stability problems arising from the fact that particularly high peak loads and voltage amplitudes will occur in the low-voltage grid of the future.

The LVRSys™ low-voltage control system is a flexible and economical alternative to conventional line extensions. Its economical use is worthwhile in all low-voltage grids in which the short-circuit power is sufficient but voltage stability problems exist. The voltage stability problems can occur locally (individual strings) or throughout the entire grid. The LVRSys™ can be used flexibly as a string controller or as a controller directly at the local network station.

EOR-3DS

The digitization unit for the future-proof local network station

The EOR-3DS in the digital local network station combines classic earth fault and short-circuit detection with the necessary digital interface functions. This turns a short-circuit and earth fault indicator into a completely new class of device: the EOR-3DS as a digitalization unit for local network substations.
For distribution network operators, the digital local network station is a crucial component for the automation, monitoring and efficient operation of their networks. These digital local substations will be an essential element of the smart grid of the future. As a result, distribution network operators are facing new challenges such as the large-scale roll-out of networked devices distributed across the entire supply network. The EOR-3DS in its function as a digitization unit for local substations enables distribution grid operators to operate large numbers of digital local substations in their grids in a future-proof manner.

What are the current or general advantages, disadvantages and challenges of smart grids/intelligent power grids?

Advantages:

  1. Energy efficiency: Smart grids optimize energy consumption and reduce waste.
  2. Integration of renewable energies: They enable the seamless integration of solar, wind and other renewable energies.
  3. Improved reliability: Automation minimizes outages and speeds up network recovery.
  4. Cost savings: Consumers can control their energy consumption better and benefit from cheaper tariffs.

Disadvantages:

  1. Costs: The implementation of a smart grid requires considerable investment in technology and infrastructure.
  2. Data protection: The collection of large amounts of personal data raises data protection concerns.
  3. Cybersecurity: Networking increases the risk of cyberattacks on the electricity grid.

Challenges:

  • Regulatory hurdles: Regulation and legislation must be adapted to support smart grids.
  • Interoperability: Different technologies and standards must be compatible with each other.
  • Public participation: Public acceptance of smart grids and consumer education are challenges.

What is the status of smart grids/intelligent power grids in Germany and the DACH region?

And what does the future hold?

In Germany and the DACH region, the development of smart grids is at an advanced stage. The spread of smart grids has increased in recent years, particularly due to efforts to integrate renewable energies and increase energy efficiency.

The framework conditions in Germany and the DACH region are characterized by political incentives to promote renewable energies, energy-efficient technologies and innovative grids. These incentives, together with research and development projects, are contributing to the further spread of smart grids.

The challenges lie in integrating a growing number of renewable energy sources, adapting the grids to increasing electromobility and ensuring data protection and cyber security.

The future of smart grids in Germany and the DACH region promises increased integration of renewable energies, improved grid stability and greater energy efficiency. As an expert in this field, A. Eberle offers valuable solutions for these future challenges in the development of the smart grid.

Do you have any further questions?

Feel free to contact us!


Contact us now

Latest news

News about LVRSys™ low-voltage control & power quality

News from the product group

EORSys – News

General Knowledge

The Future of the Distribution Grid: Focus on Digital Secondary Substations

In this technical report, Gerald Jacob (Product Manager "EORSys") uses a specific example to illustrate how distribution system operators can meet the challenges of energy transition in the medium and low-voltage grid with future-proof secondary substations.

Read more

General Knowledge

Earth fault explained – basics and functions of an electrical phenomenon

Everything you need to know about earth faults - from the basics, causes and examples to the consequences. Find out more in this article about earth fault clearing, compensation, location and the benefits of constant monitoring to ensure a safe power grid.

Read more

General Knowledge

Residual current

In this article, you will learn about residual current measurement & residual current monitoring and why it is important to measure residual current.

Read more

General Knowledge

Power Quality

Good power quality is characterized by the fact that the mains voltage actually arriving at the consumer matches the mains voltage promised by the utility company

Read more

General Knowledge

Reactive power – definition, calculation and measurement

The key role of reactive power in electrical engineering: definition, calculation, measurement and the differences to active power and apparent power. Find out how reactive power influences the efficiency of electricity grids and shapes energy transmission.

Read more

General Knowledge

What is apparent power and how is it calculated?

Apparent power is a term used in electrical engineering to describe the apparent power in an alternating current system. It is made up of the active power (the power actually used) and the reactive power (the power not used for work). The unit of apparent power is the volt-ampere (VA).

Read more

Info letter

Information Letter No. 24: Integration guide for the metering of a power plant according to the Requirements for Generators (2016/631) RfG

Integration guide for the measurement of a power plant (EZA) according to VDE-AR 4110 and VDE-AR 4120.

Read more

Info letter

Info Letter No. 23: Direction of harmonics Sources of harmonics in the power system

Le sens du flux de puissance des harmoniques est déterminé par le signe de la puissance activ

Read more

Info letter

Info Letter No. 22: Definition of power measurements according to the standards DIN 40110-2 and IEEE 1459

There is a wide range of electronic measuring devices for the digital measurement of power...

Read more

Info letter

Info Letter No. 21: The influence of the contact resistance at the earth-fault location on the zero sequence voltage UEN in compensated networks

The earth fault in compensated networks is usually presented without a contact resistance at the fault...

Read more

Info letter

Info Letter No. 19: The evaluation of power quality and detection of interference in medium voltage network

For various reasons, interest in the continuous monitoring of network quality in medium-voltage...

Read more

Info letter

Info Letter No. 18: Transient relay for high resistance, intermittent and recurrent earth faults (Part 2)

Figure 3 can also be used for the determination of static earth faults. In an isolated network the entire...

Read more

Info letter

Info Letter No. 17: Transient relay for high resistance, intermittent and recurrent earth faults (Part 1)

The statistics show that earth faults constitute a large proportion of network faults. Conventional relays...

Read more

Info letter

Info Letter No. 15: Earth fault location using the harmonic procedure (Part 2)

For the study of the behaviour of the harmonic currents and voltages in the compensated network, at...

Read more

Info letter

Info Letter No. 14: Earth fault location using the harmonic procedure (Part 1)

For the following considerations a network with three outputs and an earth fault in line 1 in output...

Read more

Info letter

Info Letter No. 8: Apparent power and reactive power in three-phase networks

The range of electromechanical and electronic measuring devices in analog - and digital technology...

Read more

Info letter

Info Letter No. 6: Detection of transient earth faults

When there is an earth fault in a conductor, at the start of the earth fault three events occur at the...

Read more

Info letter

Info Letter No. 5: Zero sequence voltage in three-phase networks

With balanced network operation and inequality of the impedances in the consumer circuit, the phase...

Read more

Special Publication

Cost Efficient Management of Digital Secondary Substations: Earth Fault Indicator EOR-3DS as Digitisation Unit for Secondary Substations

Digital secondary substations are becoming a key element for distribution system operators in terms of automation, monitoring, and efficient operations of their networks. Read this technical report about the EOR-3DS in its role as digitisation unit for secondary substations.

Read more

Special Publication

Power Quality Analysis: Tips and Tricks II

Useful tips & tricks for handling Power Quality measuring devices and typical user errors - now in our two-part article! This article provides further insights and practical tips and application examples for power quality analysis.

Read more

Special Publication

Power Quality Analysis: Tips and Tricks I

Useful tips & tricks for handling Power Quality measuring devices and typical user errors - now in our two-part article! This article explains tips and tricks for performing power quality measurements. It explains which connection errors can be made and which preliminary considerations should be made before using a measuring device.

Read more

Special Publication

Innovative & economical “system solutions” in the age of energy grid transformation

The transformation of the energy industry from a centralized structure to a decentralized energy supply is creating complex energy networks with volatile load flows and changing load flow directions. Grid feedback effects must be reduced to a tolerable level to avoid negative effects.

Read more

Special Publication

Measurement of voltage distortions in industrial grids with the PQ-Box 50

It is important to find disturbances in the system in a fast and reliable way. This report shows an example for trouble shooting with the Power Quality analyzer PQ-Box 50.

Read more

Special Publication

Performance increase in the distribution grid

Due to economic unreasonableness, grid operators are rejecting applications to connect PV systems in the low-voltage grid more often. The responsible grid planners are guided by the connection guideline VDE-AR-N 4105, in which decentralized generation facilities may only raise the voltage level in the low-voltage grid by 3% compared to the previous situation.

Read more

Special Publication

Economic Analysis Low Voltage Regulation

Smart Grids and the resulting changes in the distribution grids face many distribution grid operators with different challenges. These include...

Read more

Contact request:



* Mandatory

Your data is being processed

a-eberle kontakt newsletter ×

Our seminars &
webinars

► Register here!

x