Erdschluss-Messgerät

For Measurement in Industrial Environments

PQI-DA Smart

The PQI-DA smart is a voltage and power logger and fault recorder all in one. It has been developed for measurements on public grids, smart grids and in industrial environments up to 690V (L-L) measured voltage. The device can be used both as a power quality device and a measurement system to detect all the physical qualities of alternating current networks. This makes the device an appealing power quality all-rounder.

Further questions or want to start an enquiry? Please click “Product Enquiry”.

Battery storage & storage power plants (MV/LV)
Main and sub-distribution boards in industrial and functional buildings
Industrial plants & production facilities
Emergency power systems / emergency power supply
Residential districts with PV, charging points & heat pumps
Data centers & IT infrastructure
Local network stations (MV/LV)
Transformer stations at grid nodes
Transmission & distribution grids (HV/MV/LV)
Substations (HV/MV)
Ground-mounted photovoltaic systems
Onshore windparks
Offshore windparks
Hydroelectric power plants

Cross-Product Downloads

Special Publications
Flyer
Product Overview A. Eberle
A. Eberle Seminars in Nuremberg

PQI-DA Smart

Instruction Manual
Installation Manual
Technical Data Sheets
Release Notes
Firmware
Certificates
Interface Lists
Tender Specifications
WinPQ Lite
Project Planning Data (3D Models)

Accessories

I-Sense: Current Feeder Measurement
Mounting Panel
Rogowski Coil
Current Clamp
Divisible Differential Current Transformer
GPS Receiver Set
Modem / Remote Connection

Records Transients at up to 24 µs

Transients are increasingly a problem in electrical grids. The power logger PQI-DA smart offers the ability to measure these transients exactly down to 24 µs, allowing precise network analysis. Analysis with our device makes the grid not only more stable but also safer.

power-logger

Highly Accurate Electrical Sensors Available

Do you want to leave your measurement circuits to do their job? Then we have a cost-efficient solution for you! With the C40 feature, four power inputs for Rogowski coils are provided; with C44, four AC power inputs for mini current clamps. We have tested the C40 model's ability to measure the current in Rogowski coils; measurement errors are very linear up to 19 kHz.

Fulfill the Measurement Standards of Tomorrow Today

Our fix installed all-rounder offers a wide range of measurement options that represent the standards of tomorrow, today. Thus, our PQI-DA smart power logger already provides frequency measurement from 2 – 20 kHz. Consider buying one of our devices as investing in the solutions of the future.

Standards and Protocols – Making Our Products Fit for the Future

  • EN 50160 (2013)
  • IEC 61000-2-2
  • IEC 61000-2-12
  • IEC 61000-2-4 (Klasse 1;2;3)
  • NRS 048
  • IEEE 519
  • IEC 61000-4-30 Klasse A
  • IEC 61000-4-7
  • IEC 61000-4-15

Alternating or Direct Current – The PQI-DA Smart Measures Both

Alongside the inputs for alternating current measurement (C44) the PQI-DA power logger is also able to take mini current clamps for direct current.

IT Security From the Manufacturer With ISO 27001 Certification

Certified security via User Rights Management (URM) and Role Based Access (RBAC) thanks to highly encrypted data transmission.

Transparency in the Distribution Grid - Powered by A. Eberle

Power Quality Monitoring With »PQI-DA smart« in Combination With »I-Sense«

High-quality power quality monitoring with the option of quick and easy current drop monitoring helps to recognise trends at an early stage and offers the advantage of being able to initiate countermeasures in good time.


Measure Transformers in the Local Substation With High Precision - With the PQ Network Analysers »PQI-LV«, »PQI-DA smart« or »PQI-DE«

  • Measure voltage, current, power and power quality parameters at the transformer infeed with less than 0.1% deviation in accordance with IEC61000-4-30 Class A Ed. 3 to assess voltage quality via power quality parameters in accordance with EN50160 and IEC61000-2-2.
  • Analysis of flicker, THD, harmonics (H2H50), supraharmonics 220kHz, transients & PQ events with fault recording in the event of under- or overshoot.

Measuring, Recording and Analysing Outgoing Circuits - With the »I-Sense« Current Measurement Technology

  • Current measurement L1/ L2 / L3 / (N) with min. and max. values for up to 16 outgoing circuits.
  • Simple connection possible using existing ‘third-party devices’, such as safety edges with intelligent transformers.

Reporting - to the Point With the »WebPQ®« Analysis Software

  • »WebPQ®« software solution for quick and easy evaluation of power quality data and outgoing feeders using clear, configurable reports.

Quick Comparison: PQI-LV vs. PQI-DA Smart vs. PQI-DE

Find the Right Power Quality Analyzer for Your Application.

niederspannung-messgeraet

PQI-LV

PQI-DA Smart

PQI-DE

niederspannung-messgeraet
Application

• Secondary substation
• Depth of the grid
(cable-/light-/sub-distributors)
• Industrial power grids
(machinery/processes & plants)
• Retrofits

Voltage level

Low-voltage

Measurement: 4x Voltage, 4x Current

✔️

10.24 kHz / Optional 40.96 kHz (B1)
IEC61000-4-30 Edition 3 Class A

✔️

Supraharmonic Measurement

✔️

2 kHz to 20 kHz according to IEC61000-4-7 via software option (B1)
SCADA & Communication Protocols – Standard

✔️

CCCI, SSH, HTTP(S)
Modbus RTU & TCP (Standard)
SCADA – License Option

✔️

IEC60870-5-104 (P1), IEC61850 (P2), Modbus Master (P3) MQTT*
IT Security

✔️

Radius, RBAC, URM, encryption
Memory

✔️

1GB ~ 140 weeks with standard template
Display

Design & Mounting

DIN-rail

Dimensions

130 x 90 x 58 mm

L x W x H
Voltage Measurement

Direct

230 / 400 / 690V
Current Measurement

Rogowski coils & current sensors
350mV input

Digital Inputs and Outputs (Triggers and Alarms)

RCM Residual Current Measurement

Temperature Input

Fault Recorder / Transient Recorder

Optional

Application

• PCC / Point of Common Coupling (IEC 61000-2-2)
• POC / Point of Connection
(EN 50160)
• Secondary substation
with increased requirements
• Industrial applications

Voltage Level

Low-, medium- and high-voltage

Measurement: 4x Voltage, 4x Current

✔️

10.24 kHz / Optional 40,96 kHz (B1)
IEC61000-4-30 Edition 3 Class A+

✔️

Supraharmonic Measurement

✔️

2 kHz to 20 kHz according to IEC61000-4-7 via software option (B1)
SCADA & Communication Protocols - Standard

✔️

CCCI, SSH, HTTP(S)
Modbus RTU & TCP (Standard)
SCADA - License Option

✔️

IEC60870-5-104 (P1), IEC61850 (P2), Modbus Master (P3) MQTT*
IT Security

✔️

Radius, RBAC, URM, encryption
Memory

✔️

1GB ~ 140 weeks with standard template
Display

1.7 inches

Design & Mounting

DIN-rail,
Front panel installation using adapter

Dimensions

160 x 90 x 58mm

L x W x H
Voltage Measurement

Direct and transducer measurement

100 / 230 / 400 / 690V
Current Measurement

1A/5A measuring transformer (C30)
1A/5A protection transformer (C30)
Rogowski coils (C40)
Sensor technology (C44)
DC (C45)

Digital Inputs and Outputs (Triggers and Alarms)

2 / 2

RCM Residual Current Measurement

Temperature Input

Fault Recorder / Transient Recorder

✔️

Application

• Substations
• Industrial applications
• Grid code compliance
• High-precision frequency measurements
Residual Current Monitoring (RCM)

Voltage Level

Low-, medium- and high-voltage

Measurement: 4x Voltage, 4x Current

✔️

10.24 kHz / Optional 40.96 kHz (B1)
IEC61000-4-30 Edition 3 Class A++

✔️

Supraharmonic Measurement

✔️

2 kHz to 20 kHz according to IEC61000-4-7 via software option (B1)
SCADA & Communication Protocols - Standard

✔️

CCCI, SSH, HTTP(S)
Modbus RTU & TCP (Standard)
SCADA - License Option

✔️

IEC60870-5-104 (P1), IEC61850 (P2), Modbus Master (P3) MQTT*
IT Security

✔️

Radius, RBAC, URM, encryption
Memory

✔️

1GB ~ 140 weeks with standard template
Display

5 inches

Design & Mounting

Front panel installation
144 x 144

Dimensions

144 x 144 x 90 mm

L x W x H
Voltage Measurement

Direct and transducer measurement
Small signal transducer (E3)

3.25 / 100 / 230 / 400 / 690V
Current Measurement

1A/5A measuring transformer (C30)
1A/5A protection transformer (C30)
Rogowski coils (C40)
Mini current clamps (C44)
DC (C45)

Digital Inputs and Outputs (Triggers and Alarms)

8 / 4

RCM Residual Current Measurement

✔️

5th current feeder (30mA)
Temperature Input

✔️

PT100 / PT1000 / KTY
Fault Recorder / Transient Recorder

✔️

Do You Have Questions About
the PQI-DA Smart Measuring Device?

Our Specialists Will Be Happy to Help You!


Contact Us

Power Quality Analysis Software

Suitable for PQI-DA Smart

WebPQ®

The Easy Way to Analyse Your Power Quality Measurement Data

The new WebPQ® is the central analysis software for all fixed installed fault recorders, power quality monitoring devices and for the evaluation of the portable power quality analysers* from A. Eberle.

News From the Product Group

PQSys - News

General Knowledge

Measuring Harmonics: Detecting Disturbances in Buildings

6. March 2026

Harmonic distortion and supraharmonics can cause flicker, nuisance tripping and device malfunctions in modern buildings. This article explains how to measure harmonics at the socket outlet and interpret[...]

Read more

Blogpost

Power Quality Monitoring for Electrical Contractors - Mobile Network Quality Measurement with the PQ-Box ONE

2. March 2026

How a portable power quality analyzer like the PQ-Box ONE helps electrical professionals identify voltage disturbances, improve documentation and make reliable technical decisions.[...]

Read more

Blogpost

Power Quality Analyzer Guide: Your Entry Point for 2026

29. January 2026

Comprehensive 2026 guide to power quality analysers: selection criteria, applications, standards, and future trends for reliable power quality monitoring.[...]

Read more

Webinar

»Cyber Security« Webinar: A Challenge for European Energy Companies

3. December 2025

Webinar recording from 2025-11-26: »Cyber Security« - A Challenge for European Energy Companies[...]

Read more

Blogpost

A. Eberle at the Schwabach City Run 2025

24. November 2025

A. Eberle was represented by 37 participants at the 2025 Schwabach City Run, setting a new internal record for participation. Particularly noteworthy is Benjamin Rentsch's first place in the M 35 40 age[...]

Read more

General Knowledge

Total Harmonic Distortion (THD) in Low Voltage Networks

20. November 2025

This study examines harmonic distortion in modern low-voltage grids, showing real measurement data, key standards (EN 50160, IEC 61000-3-2/-4-30) and practical ways to reduce THD in applications such as[...]

Read more

Special Publication

Power Quality Monitoring in Buildings - A Key Factor in Modern Building Design

12. November 2025

Discover how Power Quality Monitoring in Buildings improves reliability, efficiency and grid stability. Learn more in our technical article.[...]

Read more

Special Publication

Continuous Power Quality Monitoring in the Jupiter Data Centre - Voltage Quality at Exascale Level

5. November 2025

Read more

Webinar

»PQSys« Webinar: »WebPQ®« - The New Power Quality Software for Continuous Grid Monitoring

27. October 2025

Webinar recording from 2025-09-25: »PQSys« Webinar: »WebPQ®« - The New Power Quality Software for Continuous Grid Monitoring [...]

Read more

General Knowledge

Voltage Measurement Can Improve the Quality of Supply

7. August 2025

Read more

General Knowledge

Power in Multiphase Systems

7. August 2025

This technical report highlights the special features of power transmission in three-phase systems and offers valuable insights into the optimisation and analysis of modern power grids.[...]

Read more

Blogpost

Visit From the Rudolf Diesel Technical School at A. Eberle

15. July 2025

We were happy to welcome you, Rudolf-Diesel-Fachschule! Yesterday, we had the pleasure of welcoming two classes of future electrical engineering technicians from the Rudolf-Diesel-Fachschule Nürnberg[...]

Read more

Blogpost

TOP 100 Awards 2025: Innovation for the Energy Future

15. July 2025

💡 As part of the TOP 100 Awards 2025, we were honored to receive a special recognition last week in Mainz – personally presented by TV host and science journalist Ranga Yogeshwar.[...]

Read more

Blogpost

University Excursion: Pentecost Excursion of the Friedrich-Alexander-University Erlangen-Nuremberg (FAU)

14. July 2025

As a company dedicated to innovation, education, and the energy transition, we are pleased to have once again supported the Whitsun excursion of Friedrich-Alexander University Erlangen-Nuremberg (FAU)[...]

Read more

Blogpost

Further Growth at A. Eberle

14. July 2025

Welcome to the team! We welcome our new colleagues at A. Eberle.[...]

Read more

Blogpost

Specialist Training on Power Quality

18. June 2025

On 27 May 2025, everything revolved around electricity, faults and how to recognise them in a specialist training course on power quality at the Balthasar Neumann Technical Centre in Trier (BNT).[...]

Read more

Webinar

»PQSys« Webinar: PQ-Monitoring & Feeder Current Measurement in Low-Voltage Grids 3

19. May 2025

Webinar recording from 2025-05-14: »PQSys - PQ-Monitoring & Feeder Current Measurement in Low-Voltage Grids - part 3«. [...]

Read more

Webinar

»PQSys« Webinar: Presentation: »PQI-LV« - The New PQ-Analyser for Transparency in the Low-Voltage Grid

4. March 2025

Webinar recording from 2025-02-19: »PQSys - Presentation: »PQI-LV« - The New PQ-Analyser for Transparency in the Low-Voltage Grid«. [...]

Read more

General Knowledge

Measuring the Voltage Drop

23. January 2025

The voltage drop is the difference between the voltage at the beginning and end of an electrical line. In an electrical network, the voltage can be reduced by the resistance and impedance of the lines,[...]

Read more

Product innovation

Product Announcement: »PQI-LV« Released on 05.06.2024

22. January 2025

PQI-LV - cost-efficient class A power quality analyser for precise PQ monitoring in low voltage. Available to order now.[...]

Read more

Contact request:



* Mandatory

Your data is being processed

a-eberle kontakt newsletter ×

The download started automatically in a new window.

How did you hear about us?
Consent to data transfer*

* Mandatory fields