The mobile Power Analyzer

PQ-Box 150

The PQ-Box 150 mobile power analyzer, power meter and transient recorder was designed to quickly locate the source of network disturbances. The class A device was developed for measurements in low, medium and high voltage networks and is ideally designed for mobile measurement operation in harsh environments and in very confined spaces. Thus, the device impresses as a mobile all-rounder of our product group and its wide field of application, which also provides standard reports according to the specifications of EN 50160, IEC 61000-2-2/-2-4 for public and industrial networks.

Further questions or want to start an enquiry? Please click “Product Enquiry”.

Cross-Product Downloads

Special Publications
Flyer
Feature Matrix
Product Overview A. Eberle

Accessories

Catalogue
Current Clamp
Rogowski Current Clamps
Adapter Cable Set
Calib-Box
External Power Supply
Bags
Navilog GPS Clock
NIS-Clock
Isolation Cover
Sensors

Detection of current and voltage harmonics up to 9kHz

The power analyzer PQ-Box 150 measures current and voltage harmonics up to 9 kHz according to IEC61000-4-7. The device is well prepared for future power quality standards.

power-quality-analyzer-pq-box-150

power-quality-analyzer-pq-box-150

WLAN interface for wireless communication with the software & App

In addition to a USB and ethernet interface, the data recorded by the PQ-Box 150 can be transferred to the evaluation PC via a fast WLAN interface. The comprehensive evaluation software WinPQ mobil is included in the scope of delivery and can be installed on any number of PCs. To round off the user experience, we have developed the PQ-Box app for Android and iOS. For example, via the app it is possible to display a variety of online measured values, change transformer configurations for current and voltage transformers, the measuring interval or the nominal voltage of the PQ-Box 150.

All standards and protocols fulfilled – so our products are ready for the future

The PQ-Box 150 creates an automatic norm evaluation and event recording according to:

  • EN 50160
  • IEC 61000-2-2
  • IEC 61000-2-12
  • IEC 61000-2-4
  • NRS 048
power-quality-analyzer-pq-box-150

Simple menu navigation and intuitive operation of the measuring device

When designing the menu navigation of our mobile power analyzers, we focused on enabling particularly user-friendly and intuitive navigation and thus operation of the measuring device. This means that you as a user can quickly find your way around the device when using the PQ-Box and concentrate on the essentials: the measurement. The user interface of the PQ-Box 150 is identical to that of the PQ-Box 200 and PQ-Box 300 models – also from the PQ-Box family from “A. Eberle”.

Standard accessories & device installation – how your PQ Box arrives

  • power analyzer »PQ-Box 150«
  • USB cable
  • 4mm safety sockets incl. inserts for worldwide sockets
  • 5 Delphin terminals (3x red, 1 x green, 1 x blue)
  • Case for measuring device and accessories
  • Hardware operating instructions (software instructions via website and included in software)
  • QR code for downloading WinPQ mobile software
  • TCP-IP connection cable
  • Wide-range AC/DC power supply unit for supply via test leads
  • Two black stacking plugs (stacking of measuring cable and power supply on one terminal)
  • Carrying and fastening strap

Analyse faults in the ripple control telegram with ripple control analysis

The power quality analyzer makes it possible to trigger a ripple control frequency in addition to the ripple control level measurement and to record voltages and currents for a set frequency. The complete telegram can be displayed up to a length of 210 seconds and a variety of parameters can be set in the meter (trigger threshold, recording threshold, ripple control frequency, bandwidth of the filter curve for ripple control frequency).

Do you have questions
about the PQ-Box 150?

Our specialists will be happy to help you!


Contact us

WinPQ mobile
High-quality analysis software

WinPQ mobil was designed to support the user in evaluating the data. The clear presentation of the measured values was the main focus. Thus, the software not only advances the PQ-Box, but also the user.

News from the Productgroup

PQMobil – News

General Knowledge

Harmonics

17. September 2024

Harmonics are waves whose frequencies are an integer multiple higher or lower than those of the fundamental oscillations. They arise due to non-linear loads in the grid when the electrical voltage is distorted[…]

Read more

Blogpost

International Partner Week 2024 – a Look Back

29. August 2024

Our International Partner Week 2024 – many old friends and new faces were our guests, it was a pleasure.[…]

Read more

Blogpost

PQ-Box Trade-in Promotion: Only From 1 September to 31 December 2024

5. August 2024

For a limited time: Receive a discount for the trade-in of your PQ-Box 100 or a comparable external old device (3-phase power quality analyser). Click here for further information![…]

Read more

General Knowledge

Voltage Monitoring

1. July 2024

Find out everything you need to know about voltage monitoring in this article. What is voltage monitoring, why is voltage monitoring essential for both energy supply companies and industrial companies[…]

Read more

General Knowledge

What Is Load Profile Measurement/Power Measurement?

25. June 2024

This article explains the definition and difference between load profile measurement (RLM), power measurement and measuring the standard load profile. These are important methods for accurately recording[…]

Read more

Special Publication

Ferrari´s Meter vs. Electronic Meter

9. April 2024

This technical report analyzes a power measurement at a large industrial customer. The customer records very high currents and fifth harmonic voltages during production time, which leads to poor voltage[…]

Read more

General Knowledge

Residual current

6. March 2024

In this article, you will learn about residual current measurement & residual current monitoring and why it is important to measure residual current.[…]

Read more

General Knowledge

Power Quality

6. March 2024

Good power quality is characterized by the fact that the mains voltage actually arriving at the consumer matches the mains voltage promised by the utility company.[…]

Read more

General Knowledge

Reactive power – definition, calculation and measurement

6. March 2024

The key role of reactive power in electrical engineering: definition, calculation, measurement and the differences to active power and apparent power. Find out how reactive power influences the efficiency[…]

Read more

General Knowledge

What is apparent power and how is it calculated?

6. March 2024

This article addresses the question of what apparent power is and how to calculate it. An understanding of apparent power is crucial for the correct dimensioning of inverters and therefore for the optimum[…]

Read more

Special Publication

Angle Determination of Voltage and Current Harmonics in Practice

24. August 2023

Today’s devices and equipment such as switched-mode power supplies, frequency converters, regulated drives, charging devices for e-mobiles or LED lighting work internally with high clock frequencies in[…]

Read more

General Knowledge

All „Supra“ With Your Grid?

23. May 2023

Today’s devices and equipment such as switched-mode power supplies, frequency converters, controlled drives, charging devices for e-mobiles or LED lighting work internally with high clock frequencies in[…]

Read more

General Knowledge

Power Quality Analysis: Tips and Tricks II

28. April 2023

Useful tips & tricks for handling Power Quality measuring devices and typical user errors – now in our two-part article! This article provides further insights and practical tips and application examples[…]

Read more

General Knowledge

Power Quality Analysis: Tips and Tricks I

27. April 2023

Useful tips & tricks for handling Power Quality measuring devices and typical user errors – now in our two-part article! This article explains tips and tricks for performing power quality measurements.[…]

Read more

General Knowledge

Four Ways to Measure Current

26. April 2023

The following technical report examines various methods for measuring current. It discusses how currents are measured using power analyzers and current clamps. The respective advantages and disadvantages[…]

Read more

General Knowledge

Cos ϕ vs. Power Factor λ – Practice

25. April 2023

This second technical report on the subject of reactive power and in particular the distortion reactive power supplements the first contribution “Cos ϕ vs. power factor λ – Theory”. In this article,[…]

Read more

General Knowledge

Cos ϕ vs. Power Factor λ – Theory

24. April 2023

This technical report discusses the distinction between power factor and cosine phi. Cosine Phi, formerly widely known as the ratio of active power to apparent power, however, has a different meaning for[…]

Read more

Special Publication

Mains Feedback Interferes With Protective Devices

10. October 2022

In a photography and design studio, located in a large industrial park, a RCD tripped frequently. Due to the permanent power cuts, the employees of the studio could not work properly. This article shows[…]

Read more

Special Publication

Creating Power Quality Surveys With PQ-Box and WinPQ Mobil Software

18. May 2022

The following report displays the PQ-Box and WinPQ mobil software interact to allow an evaluation of the disturbance levels at a measuring point according to approved grid norms.[…]

Read more

Special Publication

Measurement of Voltage Distortions in Industrial Grids With the PQ-Box 50

14. April 2022

It is important to find disturbances in the system in a fast and reliable way. This report shows an example for trouble shooting with the Power Quality analyzer PQ-Box 50. […]

Read more