Erdschluss-Messgerät

For measurement in industrial environments

PQI-DA smart

The PQI-DA smart is a voltage and power quality measurement device and fault recorder all in one. It has been developed for measurements on public grids, smart grids and in industrial environments up to 690V (L-L) measured voltage. The device can be used both as a power quality device and a measurement system to detect all the physical qualities of alternating current networks. This makes the device an appealing power quality all-rounder.

Have more questions or start an enquiry? Just click on “Product Enquiry”.

PQI-DA smart

Instruction Manual
Installation Manual
Technical Data Sheets
Release Notes
Firmware
Certificates
Interface Lists
Tender Specifications
WinPQ lite
Project planning data (3D models)

Accessories

I-Sense: Current Feeder Measurement
Mounting Panel
Rogowski Coil
Current clamp
Divisible differential current transformer
GPS Receiver set

Records transients at up to 24 µs

Transients are increasingly a problem in electrical grids. The PQI-DA smart offers the ability to measure these transients exactly down to 24 µs, allowing precise network analysis. Analysis with our device makes the grid not only more stable but also safer.

Highly accurate electrical sensors available

Do you want to leave your measurement circuits to do their job? Then we have a cost-efficient solution for you! With the C40 feature, four power inputs for Rogowski coils are provided; with C44, four AC power inputs for mini current clamps. We have tested the C40 model’s ability to measure the current in Rogowski coils; measurement errors are very linear up to 19 kHz.

Fulfil the measurement standards of tomorrow today

Our fix installed all-rounder offers a wide range of measurement options that represent the standards of tomorrow, today. Thus, our PQI-DA smart power quality device already provides frequency measurement from 2 – 20 kHz. Consider buying one of our devices as investing in the solutions of the future.

Standards and protocols – making our products fit for the future

  • EN 50160 (2013)
  • IEC 61000-2-2
  • IEC 61000-2-12
  • IEC 61000-2-4 (Klasse 1;2;3)
  • NRS 048
  • IEEE 519
  • IEC 61000-4-30 Klasse A
  • IEC 61000-4-7
  • IEC 61000-4-15

Alternating or direct current – The PQI-DA smart measures both

Alongside the inputs for alternating current measurement (C44) the PQI-DA power quality device is also able to take mini current clamps for direct current.

IT security from the manufacturer with ISO 27001 certification

Certified security via User Rights Management (URM) and Role Based Access (RBAC) thanks to highly encrypted data transmission.

Do you have questions about
the PQI-DA measuring device?

Our specialists will be happy to help you!


Contact us

WinPQ

The suitable Software offers the user more reasons to use the PQI-DA smart

The WinPQ system solution for all built-in A. Eberle fault recorders, power quality monitoring devices and mobile network analyzers. Monitor power quality permanently – from the high-voltage grid to the end-user in a system. Intuitive operation despite the vast amount of data handled.

News from the Productgroup

PQSys – News

General Knowledge

Residual current

6. March 2024

In this article, you will learn about residual current measurement & residual current monitoring and why it is important to measure residual current.[…]

Read more

General Knowledge

Power Quality

6. March 2024

Good power quality is characterized by the fact that the mains voltage actually arriving at the consumer matches the mains voltage promised by the utility company[…]

Read more

General Knowledge

Reactive power – definition, calculation and measurement

6. March 2024

The key role of reactive power in electrical engineering: definition, calculation, measurement and the differences to active power and apparent power. Find out how reactive power influences the efficiency[…]

Read more

General Knowledge

What is apparent power and how is it calculated?

6. March 2024

Apparent power is a term used in electrical engineering to describe the apparent power in an alternating current system. It is made up of the active power (the power actually used) and the reactive power[…]

Read more

General Knowledge

Ready for the smart grid of the future?

6. March 2024

All information about smart grids/intelligent power grids, the technology behind them, advantages, disadvantages, challenges and current distribution.[…]

Read more

Product innovation

Product announcement: »I-Sense« for feeder current measurement in future-proof secondary substations available as of 15/09/2023

16. October 2023

»I-Sense« Feeder Current Measurement for up to 16 feeders. Available to order now.[…]

Read more

Product innovation

Product discontinuation: Power Quality Analyser PQI-DA, as of 09.08.2023

9. August 2023

Power Quality Analyser PQI-DA is currently scheduled for product discontinuation.[…]

Read more

Special Publication

Power Quality Analysis: Tips and Tricks II

28. April 2023

Useful tips & tricks for handling Power Quality measuring devices and typical user errors – now in our two-part article! This article provides further insights and practical tips and application examples[…]

Read more

Special Publication

Power Quality Analysis: Tips and Tricks I

27. April 2023

Useful tips & tricks for handling Power Quality measuring devices and typical user errors – now in our two-part article! This article explains tips and tricks for performing power quality measurements.[…]

Read more

Special Publication

Innovative & economical “system solutions” in the age of energy grid transformation

2. February 2023

The transformation of the energy industry from a centralized structure to a decentralized energy supply is creating complex energy networks with volatile load flows and changing load flow directions. Grid[…]

Read more

Blogpost

DAKKS Calibration Report: PQI-DE & PQI-DA Smart With Sensational Results

11. August 2022

In the DAKKS calibration according to VDE-AR 4110 Annex F, our power quality analyzers PQI-DE & PQI-DA smart have achieved sensational accuracy values.[…]

Read more

Special Publication

Measurement of voltage distortions in industrial grids with the PQ-Box 50

14. April 2022

It is important to find disturbances in the system in a fast and reliable way. This report shows an example for trouble shooting with the Power Quality analyzer PQ-Box 50. […]

Read more

Info letter

Information Letter No. 24: Integration guide for the metering of a power plant according to the Requirements for Generators (2016/631) RfG

18. January 2022

Integration guide for the measurement of a power plant (EZA) according to VDE-AR 4110 and VDE-AR 4120.[…]

Read more

Info letter

Info Letter No. 8: Apparent power and reactive power in three-phase networks

7. September 2021

The range of electromechanical and electronic measuring devices in analog – and digital technology…[…]

Read more

Info letter

Info Letter No. 5: Zero sequence voltage in three-phase networks

7. September 2021

With balanced network operation and inequality of the impedances in the consumer circuit, the phase…[…]

Read more

Special Publication

Emergency Power Supplies in Hospitals and Data Centres

7. March 2021

According to DIN VDE 0100 part 710, if the voltage over one or more external cables providing the general power supply to a hospital falls to less than 90% of the nominal grid voltage for a period of more[…]

Read more

Special Publication

Voltage Quality at all Network Levels

7. March 2021

Extending networks will not come cheaply. For the distribution system alone, the Federal Grid Agency estimates costs of around…[…]

Read more

Contact request:



* Mandatory

Your data is being processed

a-eberle kontakt newsletter ×